Emergency Light Manufacturers Note - The lighting principle of fire emergency lighting should comply with the following conditions:

  
According to the relevant provisions of the State, "Code for Fire Protection of Building Design" and "Code for Fire Protection Design of High-rise Civil Buildings", the installation specifications for fire emergency lighting should be installed in these areas:

  
1. Close the stairwell, smoke-proof stairwell and its front room, fire elevator and its front room;

  
2, power distribution room, fire control room, automatic generator room, fire pump room, smoke and smoke exhaust passage, battery room for fire and electricity, telephone main machine room and other rooms that still need to stay in the fire in the event of fire;

  
3. The auditorium, the exhibition hall with more than 1,500 square meters on each floor, the business hall, the studio with a building area of ​​more than 200 square meters, the densely populated area or the basement with a building area of ​​more than 300 square meters;

  
4. Fire emergency evacuation walkways in public buildings and inner walkways with a length of more than 20 meters;

  
5. For personnel-intensive entertainment venues or shopping malls, the recommendations for the density of lighting emergency lighting should be appropriately increased;

  
The installation location of fire emergency lighting is mostly above the fire safety exit door frame, or the building with large space should be equipped with fire emergency lighting on the top of each column. At the same time, it should cooperate with a certain number of fire emergency signs and other fire emergency lights. ;

  
The fire emergency sign lights are generally installed and installed above the fire emergency evacuation passage (mostly double-sided fire safety exit emergency sign lights), or above the door frame of the fire escape safety exit (the wall mounting method is mostly single-sided fire emergency sign light) );

  
The installation position of the fire emergency ceiling lamp is mostly the stairway corridor, the inner walkway of the public building leading to the safety exit, and it is installed close to the ceiling. Attention should also be paid to maintenance and maintenance;

  
In some public places, fire emergency underground buried lights and in-wall fire emergency evacuation lights shall be inspected according to requirements, and the emergency discharge time of the lamps shall be checked regularly to avoid details such as obstruction of the lamps by the objects;

  
In addition, it should be noted that: fire emergency safety passages, fire hydrant boxes, etc., should avoid the accumulation of debris, keep it open. https://www.linsheng.com

  